Revealing the impact of temperature on electrochemical, DNA-based sensors to correct signaling fluctuations

27 March 2025, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Developing convenient and easy-to-use analysis tools for real-world applications requires sensing approaches that enable rapid, reagentless, and in situ quantitation of diverse molecular targets. Electrochemical, DNA-based (E-DNA) sensors meet these needs by utilizing conformational changes in electrode-bound, redox reporter-modified DNA probes upon target binding. The recognition event alters the electron transfer rate from the redox reporter, which can be monitored using square wave voltammetry by synchronizing the excitation frequency with the charge transfer rate. However, the kinetic nature of the surface-bound sensing process makes signaling strongly temperature-dependent, an aspect that has been widely overlooked and that restricts the application of E-DNA sensors to temperature-controlled environments. Here, we explore the relationship between electrochemical signal, square wave frequency, and temperature across different DNA constructs. Doing so, we identified the architectures most susceptible to temperature-induced signal fluctuations and developed two straightforward correction strategies. These approaches are particularly effective for electrochemical, aptamer-based (E-AB) sensors, enabling accurate and stable measurements over a wide temperature range, from 22 ºC to 37 ºC. By eliminating the significant influence of temperature on signaling, we broaden the applicability of E-DNA sensors, enhancing their performance for point-of-care testing, continuous molecular monitoring, and other real-world scenarios where temperature fluctuations are unavoidable.

Keywords

Temperature
Electrochemical Biosensors
DNA
Aptamers
Signal fluctuations

Supplementary materials

Title
Description
Actions
Title
Supplementary Material for Revealing the impact of temperature on electrochemical, DNA-based sensors to correct signaling fluctuations
Description
Experimental details, DNA sequences, square wave voltammograms collected with different DNA constructs, stability of the SAM at high temperatures, signal fluctuations of different sensors, charge transfer map for the Gli4T aptamer, hybridization kinetics of PolyT and PSAG1T, signal change of vancomycin aptamers at different frequencies, and temperature-dependence signal correction for tobramycin sensors are included as part of the Supporting Information.
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.