Influence of anticoagulant on the spectroscopic analysis of drying blood pools

03 October 2024, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Over the course of a few minutes, untreated whole blood undergoes a clotting cascade making forensic research that investigates “fresh” bloodletting events difficult. In bloodstain pattern analysis research, whole blood treated with anticoagulant is often used to prolong the usability of the blood and allow for transport and experimentation to simulate pattern formation using “fresh” clot-free blood. Anticoagulants bind to components of this cascade making them unavailable to participate in coagulation, preventing the formation of clots. In this work, we investigate the spectral implications of anticoagulant addition for time since deposition (TSD) estimation methods, particularly of larger volume blood pools. We characterized the differences in spectral profiles of blood pools with and without a citrate-based anticoagulant using visible absorbance spectroscopy, attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Across all methods, notable spectral differences were observed, namely the red-shift in the Soret peak maxima (visible), delayed increase in the 1532 cm-1 peak (ATR-FTIR), and increased accessibility of iron (XPS) in pools treated with ACD-A. Principal component analysis and partial least squares discriminant analysis (PLS-DA) were used to further assess the variation in the visible absorbance and ATR-FTIR spectra over time. The blood pools differed most significantly in the first week following deposition due to the addition of the water in the anticoagulant, slowed desiccation, and lack of clotting in the treated blood pools. At timepoints exceeding one week following deposition, the spectral profiles of the pools regained similarity. In summary, the fluid choice, and particularly the inclusion of anticoagulant is an important consideration during experimental design and TSD estimation method development.

Supplementary materials

Title
Description
Actions
Title
Supplementary Information
Description
Supplementary Information
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.