In-line Thermal Desorption and Dielectric Barrier Discharge Ionization for Rapid Mass Spectrometry Detection of Explosives

10 June 2024, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Thermal desorption (TD) of wipe-based samples was coupled with an in-line dielectric barrier discharge ionization (DBDI) source and rugged compact time-of-flight mass spectrometer (MS) for the detection of explosives, propellants, and post-blast debris. The chromatography-free TD-DBDI-MS platform enabled rapid and sensitive detection of organic nitramine, nitrate ester, and nitroaromatic explosives, as well as black powder and black powder substitute propellants. Parametric investigations characterized the response to TD temperature, and optimized DBDI voltage, aerodynamically assisted entrainment, and fragmentation through in-source collision induced dissociation (isCID). Excess nitrate generated by the DBDI source yielded predominantly nitrate-adduct formation. Sub-nanogram sensitivities were demonstrated for all explosives investigated, except for nitroglycerin, specifically due to its volatility. Further, most analytes/explosives exhibited tens of picogram sensitivities. The platform also demonstrated the detection of propellant and military explosives from post-blast debris. The TD-DBDI-MS system performed well without the need for aerodynamically assisted entrainment (and the associated rough pump), which along with requiring no additional gasses (i.e., N2 ¬or He) or solvents, aid in potential field deployment. The ease of TD-DBDI attachment and removal added trace solid or liquid residue detection to the rugged mass spectrometer, designed primarily for analysis of volatile organic and inorganic compounds.

Keywords

Trace detection
Dielectric barrier discharge ionization
Mass spectrometry
Explosives
Time-of-flight
Propellants
Swipe sampling

Supplementary materials

Title
Description
Actions
Title
Supporting Information for: In-line Thermal Desorption and Dielectric Barrier Discharge Ionization for Rapid Mass Spectrometry Detection of Explosives
Description
Additional experimental method details, mass spectra, and figures as noted in the text can be found in the supporting information.
Actions

Supplementary weblinks

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.