Monitoring WAD Cyanide Concentration in River Waters with a Glassy Carbon Electrode Modified with 9,10-Phenanthroquinone

27 September 2023, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Heavy metal-containing industrial effluent streams from electroplating and metalworking industries represent a major environmental issue. They contain metal cyanide complexes ([Ni(CN)4]2- and [Cu(CN)3]2-) referred to as weak acid dissociable cyanide (CN-WAD), which require continuous in situ monitoring. In this scenario, a glassy carbon (GC) electrode superficially decorated with 9,10-phenanthroquinone (FNQ) is manufactured and employed for the simultaneous electrochemical monitoring of cyanide WAD complexes. The interaction between GC and FNQ was characterized by Raman and electrochemical impedance spectroscopies, cyclic voltammetry, and chronocoulometry. The electrochemical evaluation was conducted by differential pulse voltammetry (DPV) and CV. The GC/FNQ electrochemical sensor simultaneously detected cyanide complexes with an average linear range of 9.09 - 92.8 μmol L-1, and a detection limit of 1.47 ± 0.11 μmol L-1 and 1.2 ± 0.6 μmol L-1 for [Ni(CN)4]2- and [Cu(CN)3]2-, respectively. The sensor demonstrated remarkable selectivity in the presence of multiple interfering species with a percentage variation range of 89.2-109.4%. Moreover, a computational DFT study provided valuable insights into the electrode/electrolyte interface. Finally, the developed sensor was applied for the electrochemical detection of WAD cyanide in river water samples.

Keywords

10-phenanthroquinone
electrochemical sensor
[Ni(CN)4]2-
[Cu(CN)3]2-
DFT

Supplementary materials

Title
Description
Actions
Title
Monitoring WAD Cyanide Concentration in River Waters with a Glassy Carbon Electrode Modified with 9,10-Phenanthroquinone
Description
Complementary analysis of the developed sensor (Glassy Carbon Electrode Modified with 9,10-Phenanthroquinone) for detection the WAD Cyanide Concentration in River Waters
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.