An Automated and Lightweight Framework for Electrolyte Diagnostics using Quantitative Microelectrode Voltammetry

07 July 2023, Version 2
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Voltammetry is a ubiquitous electroanalytical method that can be used to help probe sustainable electrochemical technologies. When conducted with a microelectrode (radius ca. μm), voltammetry enables special interrogation of electrolyte solutions by minimizing distortions and facilitating near-steady-state measurements. Methodologies aimed to evaluate the behavior of redox-active species often leverage well-established, physically-grounded expressions that can be extended to examine electrolyte solutions under non-ideal conditions (e.g., signal convolution from multiple redox events) by simulating the entire voltammogram. To characterize these analyte systems, we first develop closed-form expressions—building on previous work that utilizes oblate spheroidal coordinates—and establish a framework for rapidly evaluating electrolyte composition. We subsequently apply finite difference transient voltammogram models to assess the performance of this workflow. We then validate our findings using model, deterministically-prepared nonaqueous electrolyte solutions containing N-[2-(methoxyethoxy)ethyl]phenothiazine, finding the toolkit is particularly adept at rapidly (< 1 min) estimating the degree to which an electrolyte solution is charged (its “state-of-charge”) and remains intact (its “state-of-health”). Finally, we highlight potential extensions of this method towards advancing in situ or operando diagnostic methods within operating electrochemical devices.

Keywords

Ultramicroelectrode voltammetry
Simulation
Feature estimation
State-of-charge
State-of-health
In-situ diagnostics

Supplementary materials

Title
Description
Actions
Title
Supplementary Information for "An Automated and Lightweight Framework for Electrolyte Diagnostics using Quantitative Microelectrode Voltammetry"
Description
The Supplementary Information provides additional details and analyses not included in the main text.
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.