Open Circuit Potential Decay Transients Quantify Non-Equilibrium Local pH During Electrocatalysis

21 June 2023, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Many key energy conversion reactions are proton-coupled electron transfer (PCET) reactions that consume or generate protons at electrode surfaces. Thus, catalytic turnover can generate non-equilibrium local pH environments at the surface that differ substantially from that of the bulk. Quantitative insight into the magnitude of this interfacial pH swing is a prerequisite for understanding and designing efficient systems for energy conversion, but is difficult to measure, particularly under high current density operation; with complex gas diffusion electrodes (GDEs); and with membrane-decorated surfaces employed in functional devices. Herein, we develop and validate a general methodology for experimentally quantifying interfacial pH swings using open circuit potential (OCP) decay transients. Using this method, we quantify the impact of buffer strength, supporting electrolyte composition, and the presence of cation exchange polymer overlayers on the polarization-induced pH swing on Pt GDEs. We find that modest current densities of −30 mA cm−2 are sufficient to sustain pH swings of > 2 pH units, even for strongly buffered solutions. Meanwhile, the addition of alkali supporting electrolyte to unbuffered, acidic electrolyte can induce pH swings so large that the polarized electrode environment becomes strongly alkaline. The presence of a Nafion polymer overlayer containing fixed anionic charges serves to further augment the interfacial pH swing, resulting in a similar pH swing at half the applied current density. The transport characteristics of these systems were analytically modelled, enabling direct calculation of boundary layer thickness and quantitative prediction of the OCP decay transient. These studies establish methods for quantifying local pH swings and highlight the dramatic variation in local pH relative to the bulk under many electrolyte conditions.

Keywords

gas diffusion electrode
proton-coupled electron transfer
reversible hydrogen electrode
hydrogen evolution reaction
boundary layer thickness
platinum
pH swing

Supplementary materials

Title
Description
Actions
Title
Open Circuit Potential Decay Transients Quantify Non-Equilibrium Local pH During Electrocatalysis_SI
Description
Supplementary Information for the manuscript
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.