Self-Calibrated Ion-Selective Electrodes

17 May 2023, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Ion-selective electrode (ISE) potentiometry is reliable only if on-site calibration using a standard solution is performed before the ion measurement. The complex device and operation required for calibration hinder the implementation of ISEs in decen-tralized sensing. Reported herein is a new type of ISE that is calibrated by a built-in component of the sensor without requir-ing any fluid handling processes. The indicator and reference electrodes are connected by a thin ionic conductor such as an aqueous phase containing the measuring ions in a capillary tube. This connection establishes a baseline electromotive force (EMF) that incorporates phase boundary potentials across multiple interfaces of the electrochemical cell and serves as a one-point calibration. Unlike conventional ISEs relying on absolute EMF readings, the proposed sensor utilizes a sample-induced EMF change relative to the baseline for ion measurements. The variability in relative EMF is found to be < 2.0 mV for multiple full potentiometric sensors consisting of plasticizer-based K+ ISEs and hydrogel-based Ag/AgCl reference elec-trodes. This value is significantly smaller than the variability of absolute EMF readouts in similar sensors without the self-calibration design. Moreover, when the ion-conducting calibration bridge has a low concentration of primary ions, low ion mobility, and/or a small contact area with the indicator and reference phases, it does not compromise the Nernstian response slope toward the analyte ions in the sample and therefore does not need to be removed for sample testing. The accuracy of single-use self-calibrated K+ sensors in testing undiluted human blood samples is validated using a commercial blood gas analyzer as the reference method. This fluidics-free self-calibration strategy opens up new opportunities for ion sensing in disposable, wearable, and implantable devices.

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.