Tripeptide-assisted gold nanocluster formation for sensing Fe3+ and Cu2+

08 April 2022, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Over the past decade, various fluorescent gold nanoclusters (AuNCs) have been studied for their potential as metal ion sensors. Due to the importance of the surface ligand in stabilizing nanocluster and sensing target metal ions, there is a great need of further investigations into possible surface ligands to develop selective and sensitive sensors. In this study, we designed very simple tripeptides to form fluorescent AuNCs by taking advantage of the reduction capability of tyrosine under alkaline conditions. In addition to studying the role of tyrosine in forming AuNC, we also investigated the role of tyrosine in sensing metal ions. Two tripeptides, tyrosine-cysteine-tyrosine (YCY) and serine-cysteine-tyrosine (SCY), were prepared and used for the formation of AuNCs. We obtained AuNCs with blue and red fluorescence from YCY peptides and AuNCs with blue fluorescence from SCY peptides. We found that the fluorescence of blue fluorescence-emitting YCY- and SCY-AuNCs is selectively quenched with Fe3+ and Cu2+, while the fluorescence of the red fluorescence-emitting YCY-AuNC is stable with 13 different metal ions. We have observed that the number of tyrosine residues affects the response of sensors. In the presence of different metal ions, different aggregation propensities were observed from DLS measurement. These results suggest the chelation between the peptide on the AuNC surface and the target ions results in aggregation and causes fluorescence quenching. Our study has shown that very simple and short peptides can be designed rationally for the formation of fluorescent AuNCs and utilized as the surface ligand for the metal ion sensing.

Keywords

Nanocluster
Fluorescence
Metal sensor
Peptide

Supplementary materials

Title
Description
Actions
Title
Supplementary Information
Description
LC-MS/MS of (a) YCY and (b) SCY, UV-Vis absorption and fluorescence intensity of the fractions from the size exclusion chromatography
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.