A Novel Paper-Based Cytometer for the Detection and Enumeration of White Blood Cells According to their Immunophenotype

14 March 2022, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Total and differential white blood cell (WBC) counts are a vital metric used routinely by clinicians to aid in the identification of diseases. However, the equipment necessary to perform WBC counts restricts their operation to centralized laboratories, greatly limiting their accessibility. While several approaches have emerged to address this issue, the resulting handheld analyzers or microfluidic devices have costs and/or cumbersome external equipment that limit their widespread adoption as point-of-care cytometers. More established solutions for the development of point-of-care assays, namely lateral flow immunochromatographic assays and paper-based microfluidic devices, are inherently limited in their ability to support the detection of WBCs due to design constraints—the pore sizes of the materials used to fabricate these devices (e.g., nitrocellulose membranes or cellulosic chromatography papers) do not permit passive WBC transport via wicking. Herein, we identify a material capable of the unimpeded transport of WBCs in both the lateral and vertical directions: a coffee filter. This innovation facilitates the creation of the first paper-based cytometer. Through in situ labeling with an enzyme-labeled affinity reagent, our paper-based cytometer enumerates WBCs according to their immunophenotype. Using two cultured leukocyte lines (Jurkat D1.1 T cells and MAVER-1 B cells), we demonstrate the specific, colorimetric enumeration of each target cell population across the physiological range for total lymphocytes, 1000–4000 cells μL-1. This breakthrough demonstration paves the way for a new class of paper-based devices—those capable of controlled white blood cell transport, labeling, capture, and detection—thus expanding the opportunities for low-cost, point-of-care cytometers.

Keywords

paper-based microfluidic devices
µPAD
point of care
cytometry
porous materials
white blood cell counts
immunophenotyping
paper analytical device

Supplementary materials

Title
Description
Actions
Title
Supporting Information for Murray et al. (Paper Cytometer)
Description
Materials and Methods. Tables and figures depicting results from the material screen, figures and tables depicting results and analyses from the porosimetry characterization of select materials, flow cytometry results, the process for image analyses, results from statistical analyses, tables and figures depicting results from an additional cell count validation experiment, results from an additional fluorescent cell mapping experiment, preliminary results for limits of detection for a paper-based device enumerating B cells.
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.