CoreView: Fresh Tissue Biopsy Assessment at the Bedside Using a Millifluidic Imaging Chip

02 June 2021, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Minimally invasive core needle biopsies for medical diagnoses have become increasingly common for many diseases. Although tissue cores can yield more diagnostic information than fine needle biopsies and cytologic evaluation, there is no rapid evaluation at the point-of-care for intact tissue cores that is low-cost and non-destructive to the biopsy. We have developed a proof-of-concept 3D printed millifluidic histopathology lab-on-a-chip device to automatically handle, process, and image fresh core needle biopsies. This device, named CoreView, includes modules for biopsy removal from the acquisition tool, transport, staining and rinsing, imaging, segmentation, and multiplexed storage. Reliable removal from side-cutting needles and bidirectional fluid transport of core needle biopsies from five tissue types has been demonstrated with 0.5-mm positioning accuracy. Automation is aided by a MATLAB-based biopsy tracking algorithm that can detect the location of tissue and air bubbles in the channels of the millifluidic chip. With current and emerging optical imaging technologies, CoreView can be used for a rapid adequacy test at the point-of-care for tissue identification and glomeruli counting from renal core needle biopsies, and has the potential to be used for breast cancer diagnosis, phenotyping, and mapping of enriched tumorous regions for downstream analyses in global health applications.

Keywords

Lab-on-a-Chip
Millifluidics
Total Analysis Systems
Rapid onsite evaluation
Adequacy
triage
slide-free histology
Core Needle Biopsy
pathology
histopathology
3D printing

Supplementary materials

Title
Description
Actions
Title
Supplemental
Description
Actions
Title
Movie S1
Description
Actions
Title
Movie S2
Description
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.