Multiplexed Affinity Measurements of Extracellular Vesicles Binding Kinetics

11 January 2021, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Extracellular vesicles (EVs) have attracted significant attention as impactful diagnostic biomarkers, since their properties are closely related to specific clinical conditions. However, designing experiments that involve EVs phenotyping is usually highly challenging and time-consuming, due to laborious optimization steps that require very long or even overnight incubation durations. In this work, we demonstrate label-free, real-time detection and phenotyping of extracellular vesicles binding to a multiplexed surface. With the ability of label-free kinetic binding measurements using the Interferometric Reflectance Imaging Sensor (IRIS) in a microfluidic chamber, we successfully optimize the capture reaction by tuning various assay conditions (incubation time, flow conditions, surface probe density and specificity). A single (less than 1 hour) experiment allows for characterization of binding affinities of the EVs to multiplexed probes. We demonstrate kinetic characterization of 18 different probe conditions, namely three different antobodies, each spotted at six different concentrations, simultaneously. The affinity characterization is then analyzed through a model which considers the complexity of multivalent binding of large structures to a carpet of probes, and therefore introduces a combination of fast and slow association and dissociation parameters. Additionally, our results confirm higher affinity of EVs to aCD81 with respect to aCD9 and aCD63. Single-vesicle imaging measurements corroborate our findings, as well as confirming the EVs nature of the captured particles through fluorescence staining of the EVs membrane and cargo.

Keywords

Label-free biosensor
Extracellular vesicles (EVs)
EVs detection and characterization
Microarray
Interferometric imaging

Supplementary materials

Title
Description
Actions
Title
LowMagExo SuppInfo
Description
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.