Temperature-Dependent Charge Carrier Transfer in Colloidal Quantum Dot/Graphene Infrared Photodetectors

13 August 2020, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Colloidal PbS quantum dot (QD)/graphene hybrid photodetectors are emerging QD technologies for affordable infra-red light detectors. By interfacing the QDs with graphene, the photosignal of these detectors is amplified, leading to high responsivity values. While these detectors have been mainly operated at room temperature, low-temperature operation is required for extending their spectral sensitivity beyond a wavelength of 3 μm. Here, we unveil the temperature-dependent response of PbS QD/graphene photodetectors by performing steady-state and time-dependent measurements over a large temperature range of 80–300 K. We find that the temperature dependence of photo-induced charge carrier transfer from the QD layer to graphene is (i) not impeded by freeze-out of the (Schottky-like) potential barrier at low temperatures, (ii) tremendously sensitive to QD surface states (surface oxidation), and (iii) minimally affected by the ligand exposure time and QD layer thickness. Moreover, the specific detectivity of our detectors increases with cooling, with a maximum measured specific detectivity of at least 1010 Jones at a wavelength of 1280 nm and temperature of 80 K, which is an order of magnitude larger compared to the corresponding room temperature value. The temperature- and gate-voltage-dependent characterization presented here constitute an important step in expanding our knowledge of charge transfer at interfaces of low dimensional materials and towards the realization of next-generation optoelectronic devices.

Keywords

Lead sulfide
graphene
photodetector
low-temperature

Supplementary materials

Title
Description
Actions
Title
SUPPLEMENTARY Temperature Dependent QDs-Graphene Photodetectors
Description
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.