Practical Implications of Using a Solid Electrolyte in Batteries with Sodium Anode: A Combined X-ray Tomography and Model-based Study

07 February 2019, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Herein X-ray tomography of cycled symmetric sodium cells with Na-β-alumina is used to validate the success of a protective layer. X-ray imaging after cell failure reveals that the solid electrolyte unexpectedly broke apart alongside a crack. The crack might have acted as the nucleation site for sodium dendrite growth, which ended in short-circuiting and cell failure.

Keywords

Metal Anodes
Solid Electrolytes
X-ray tomography
Simulation
Metal-Oxygen Battery

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .